STANDARD BOXWOOD STOVE
Model BX26E Owners Manual

(Save this manual for future reference. Go to PDF format for printing.)

 

READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

DO NOT USE THIS STOVE IN A MOBILE HOME, MANUFACTURED HOME, TRAILER OR TENT – NO EXCEPTIONS!


NOTE: This stove is
NOT a UL listed stove.

SAFETY INSTRUCTIONS

SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.

Read All Instructions Carefully.

  1. The installation of this stove must comply with your local building code rulings. Please observe the clearances to combustibles (see figure 1 & figure 2).
  2. Do not install this stove in a mobile home, manufactured home, trailer or tent (NO EXCEPTIONS! per HUD FederalStandard: 24 CFR Ch.XX)..
  3. Verify that the stove is properly installed before firing the stove for the first time. After reading these instructions, if you have any doubt about your ability to completely our installation properly, you must obtain the services of a professional licensed installer familiar with all aspects of safe and correct installation. DO NOT use temporary or makeshift compromises during installation..
  4. If any parts are missing or defective, please notify the dealer or manufacturer immediately. DO NOT OPERATE A STOVE THAT IS MISSING ANY PARTS!
  5. Do not tamper with combustion air control beyond normal adjustment capacities.
  6. Always connect this stove to a chimney and vent to the outside. Never vent to another room or inside a building. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
  7. DO NOT CONNECT a wood burning stove to an aluminum Type B gas vent. This is not safe. Use approved masonry or a UL 103 HT Listed Residential Type and Building Heating Appliance Chimney. Use a 6" diameter chimney or larger, that is high enough to give a good draft (see specifics in chimney maintenance instructions.)
  8. Be sure that your chimney is safely constructed and in good repair. Have the chimney inspected by the fire department or a qualified inspector. Your insurance company may be able to recommend a qualified inspector.
  9. Creosote or soot may build up in the chimney connector and chimney and cause a house/building fire. Inspect the chimney connector and chimney twice monthly during the heating season and clean if necessary (see Maintenance & Service Hints).
  10. In the event of a chimney fire, turn the air control to closed position, leave the building and CALL THE FIRE DEPARTMENT IMMEDIATELY! Have a clearly understood plan onhow to handle a chimney fire by contacting your local fire authority for information on proper procedures in the event of a chimney fire.
  11. To prevent injury, do not allow anyone to use this stove who is unfamiliar with the correct operation of the stove.
  12. Do not operate stove while under the influence of drugs or alcohol.
  13. Ashes should not be allowed to accumulate higher than the slide damper. Dispose of ashes in a metal container with a tight fitting lid. Keep the closed container on a noncombustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or picked up by a refuse collector.
  14. The special paints used on your stove may give off some smoke and an odor while they are curing during the first 12 to 15 fires. Additional smoke and odor may be emitted from the light oils used in construction of the fire box. This should disappear after a short period of time and not occur again. Persons with lung conditions or owners of susceptible domestic pets (such as birds) should take prudent precautions. Open windows and doors as needed to clear smoke and/or odor. Paint discoloration will occur if the stove is overfired.
  15. This stove has a painted surface which is durable but it will not stand rough handling or abuse. When installing your stove, use care in handling. Clean with soap and warm water when stove is NOT hot. Do not use any acids or scouring soap, as these solvents wear and dull the finish.
  16. While stove is in operation, all persons, especially young children should be alerted to the hazards from high surface temperatures. Keep away from a hot stove to avoid burns or clothing ignition.
  17. If small children will be in the same room as the stove during operation, provide a sturdy barrier to keep them at a save distance from the stove. NEVER LEAVE SMALL CHILDREN UNSUPERVISED when they are in the same room as the stove.
  18. Keep stove area clear and free from all combustible materials, gasoline, and other flammable vapors and liquids.
  19. To prevent burns, always wear protective clothing, leather hearth gloves and eye protection, while tending the fire.
  20. While in operation, keep the feed door closed and secured at all times except while tending the fire.
  21. Do not over fire the stove. Overfiring will occur if the feed door is left open during operation. Such actions can result in very dangerous operating conditions.
  22. All power cords and electrical appliances and/or assemblies must be kept outside of the clearance dimensions shown in this manual for combustible materials.
  23. For further information on using your stove safely, obtain a copy of the National Fire Protection Association (NFPA) publication, "Using Coal and Wood Stoves Safely" NFPA No. HS-10-1978. The address of the NFPA is:
    Battery March Park, Quincy, MA  02269.
NOTE: A PROFESSIONAL, LICENSED HEATING AND COOLING CONTRACTOR SHOULD BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE.

ASSEMBLY INSTRUCTIONS

NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages.

 

TOOLS REQUIRED MATERIALS REQUIRED

Safety Glasses

Hearth Gloves

Pencil

6 foot Folding Rule or Tape Measure

Tin Snips

Drill: Hand or Electric

1/8" diameter Drill Bit
(sheet metal screws)

Screwdrivers
(blade and Phillips types)

5/16" Nut Driver or Ratchet with 5/16" Socket (for 1/4" Hex Nuts)

11mm Nut Driver or Ratchet with 11mm Socket (for Stove Bolts)

(NOTE: The following items are NOT included with your stove)

Flooring Protection: 36" x 54" as specified 
(see Locating Stove)

Chimney Connection: 6" black steel (24 gauge min.) straight or elbow (as required)

1/2" Sheet Metal Screws

Chimney: Existing 6" Lined Masonry Chimney or 6" Inside Diameter listed Type HT chimney.

Furnace Cement (manufacturer recommends Rutland Code 78 or equivalent)

  

Refer to diagram and parts list.
CAUTION: STOVE IS HEAVY. MAKE SURE YOU HAVE ADEQUATE HELP AND USE PROPER LIFTING TECHNIQUES WHENEVER MOVING STOVE.
  1. Uncrate the stove and remove cardboard packing and protective poly bag. (Save exterior cardboard for further assembly.)
     
     
  2. Remove parts from inside firebox of stove. Parts include:
      one swing top (# 9)
      two lids (#1 0)
      one lid support (# 11)
      one damper collar (# 13)
      one feed door (# 7)
      one lid lifter (# 15)
      one slide damper (# 5)
      four legs (# 1)
      hardware pack (# 16)
      S-Hook (# 17)
     
     
  3. Place flattened carton on floor and carefully turn stove over onto carton.
     
     
  4. Attach the rear legs to base of stove with:
      long stove bolts (B)
      flat washer (E)
      hex nut (F)
      (see ill. A and B)
     
     
  5. Attach hearth to bottom of stove with:
      two short stove bolts (A)
      washers (E)
      hex nuts (F)
      (see ill. C)
     
     
  6. Attach the front legs to hearth with:
      long stove bolts (B)
      flat washers (E)
      hex nuts (F)
      (see ill. D)
     
     
  7. Carefully lift stove upright and place in desired location (see following instructions for properly locating stove).

     
  8. Attach damper collar to rear top surface of stove using:
      short stove bolts (A)
      flat washers (E)
      hex nuts (F)
      (see ill. E)
     
     
  9. Place swing top in position on top of stove.
    To install, position at approximately 45 degree angle to stove (dashed lines in ill. F) until pins drop into locator holes then swing into position.
    (see ill. F)
     
     
  10. Place lid support and two lids in position on swing top.
    (see ill. F)
     
     
  11. Place the slide draft into position on the hearth.
    Hold in position with:
      round head stove bolt (C)
      large flat washer (D)
      (see ill. G)
     
     
  12. Lower feed door into position while aligning hinge pins.
      (see ill. G)

     
  13. Place S-Hook in hole at left front corner of hearth. 
    Note:
    S-Hook is used to hang lid lifter while not in use.







Locating Stove

Proper clearances must be maintained for adequate air circulation. Adequate ventilation must be provided while operating this stove.
 

CAUTION: (FIRE HAZARD) CARPETING AND OTHER COMBUSTIBLE MATERIAL MUST NOT COVER THE FLOOR PROTECTOR. THESE MATERIALS MUST REMAIN OUTSIDE OF COMBUSTIBLE CLEARANCES. SEE figure 1 and figure 2
  1. The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a listed floor protector, such as Hy-C or Imperial Model UL 3654BK or equivalent. The base must extend at least 16" beyond the front of the hearth, 8" to the sides of the stove, and must extend under the stove pipe if it is elbowed towards a wall (see figure 1 and consult local building codes and fire protection ordinances.)
  2. The stove must have its own flue. Do not connect this unit to a chimney flue serving other appliances.
  3. After observing the clearances to combustible materials (see figure 1 & figure 2), locate your floor protector accordingly (figure 1) and carefully place the stove in your selected location. Install stove pipe, elbows, and thimble as required, utilizing either a recently cleaned and inspected 6" masonry chimney or a 6" i.d. listed chimney. Maximum 64 square inches.
  4. Use 6" round black stove pipe, not galvanized stove pipe. Secure pipe sections with three (3) sheet metal screws in each stove pipe and/or elbow joint to firmly hold the pipe sections together. Do Not connect this stove to any air distribution or duct system.
  5. Recheck clearances from the stove, connector stove pipe, and corner clearances using the illustrations (figure 1 & figure 2) and your local building codes or fire protection ordinances.
    NOTE:
    Drywall faced with brick or stone should be considered a combustible surface.
  6. DO NOT INSTALL THIS STOVE IN A MOBILE HOME, MANUFACTURED HOME, TRAILER OR TENT – NO EXCEPTIONS! (HUD Federal Standard: 24 CFR Ch.XX)
  7. The clearances provided are minimum dimensions determined by NFPA. Installation of this stove must comply with the latest edition of NFPA 211 for reduced clearances and/or your local building code rulings. Use which-ever minimum dimensions are LARGEST.
    Failure to follow these minimum clearance requirements may result in an unsafe installation and could cause a fire.
  8. This stove is NOT a UL listed stove.

Fig. 1    Minimum Clearance Dimensions from Combustible Surfaces:

Fig. 2   Top View:  Minimum Corner Clearances from Combustible Surfaces

MINIMUM CLEARANCES
TO COMBUSTIBLE SURFACES

Unit to Sidewall .............................. 36 inches

Unit to Backwall ............................. 36 inches

Unit Corner to Wall ......................... 36 inches

Pipe Connector to Backwall ........... 38 inches

Pipe Connector to Ceiling .............. 18 inches


 
CAUTION: KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS AWAY FORM THE STOVE.

Pipe Installation

  1. The smooth end of the stovepipe fits over the cast iron damper collar.
  2. Horizontal pipe runs must slope upwards towards the chimney at least 1/4" per foot of horizontal run.
  3. You must have at least 18 inches of clearance between any horizontal piping and the ceiling.
  4. The pipe cannot extend into the chimney flue (figure 3).
  5. Secure pipe/elbow sections with three (3) sheet metal screws at each joint to make the piping rigid.
  6. It is recommended that no more than two (2) 90° bends be used in the stovepipe installation. The use of more than two 90° bends may decrease the amount of draw and possibly cause smoke spillage. Where possible, use only corrugated (nonadjustable) elbows. These provide a better seal.
  7. The connector pipe must not pass through an attic or roof space, closet, or any concealed space, or floor, ceiling, wall or combustible construction. A UL 103 HT Listed chimney must be used from the first penetration of ceiling or wall to the chimney cap. Never use single wall connector pipe as a chimney - a house fire could result.
NOTE: Stove pipe is NOT INCLUDED. To purchase pipe, visit your local hardware, HOME or building center. See Locating Stove for additional specifications.

 

Fig. 3  Stovepipe/Flue Connections:

CORRECT WRONG WRONG



Chimney Connections  

Chimneys perform two functions.  

  1. As a means of exhausting smoke and flue gases which are the result of fuel combustion. 
  2. The chimney provides "draft" which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. This stove relies on natural draft to operate.

NOTICE: Always provide a source of fresh air into the room where the stove is located. Failure to do so may result in air starvation of other fuel burning appliances and the possible development of hazardous conditions, fire or death.

As of April 1, 1987 all wood stoves should be installed using a factory built chimney that meets the "Type HT" requirement of UL 103 (when using a factory built chimney).

Your stove itself does not create draft. Draft is provided by the chimney. To achieve proper draft your chimney must meet the three minimum height requirements. (see figure 4, figure 5, figure 6 and figure 7). A minimum of 0.05 w.c. (measured in water column) is required for proper drafting to prevent back puffing, smoke spillage, and to maximize performance. (Gauges to measure draft are readily available at stove stores and are economical to rent or purchase.)

Factors such as wind, barometric pressure, trees, terrain and chimney temperature can have an adverse effect on the draft. The manufacturer cannot be held responsible for external factors leading to less than optimal drafting.

Should you have a problem with inadequate draft, you should contact a licensed heating and cooling contractor for assistance in solving the problem.

IMPORTANT Installation Points

  1. Size the chimney flue to the stove pipe. This stove requires a 6" diameter flue.

  2. Never connect this unit to a chimney serving another appliance.

  3. The chimney must meet all minimum height requirements.

  4. Never use a chimney to ventilate a cellar or basement.

  5. Contact your local building authority for approved methods of installation and any necessary permits and/or inspections.

Masonry Chimney
 
Before using an existing masonry chimney, clean the chimney, inspect the flue liner and make any repairs needed to be sure it is safe to use. Make repairs before attaching the stove. The connector stove pipe and fittings you will need to connect directly to a masonry chimney are shown in figure 4.

If the connector stove pipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local building and fire codes and latest edition of NFPA 211.

Fig. 4   Masonry Chimney Connection

If there is a cleanout opening in the base of the chimney, close it tightly.

Fig. 5  
Chimney Construction Through Attic Space:

Manufactured Chimney

REFER TO CHIMNEY AND CHIMNEY CONNECTOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE.

Use only 6” diameter listed chimney UL 103HT. Chimney made to this listing is High Temperature rated to 2100 degrees Fahrenheit. Use chimney from only one manufacturer. Never mix brands. Carefully follow the chimney manufacturer’s stated requirements and clearances. Use the chimney manufacturer’s attic guards, roof supports, flashing and fire stops when passing through a ceiling. Use a listed thimble when passing through a combustible wall. Do not use make-shift compromises during installation. Never use a single-wall connection pipe as a chimney!

When using a pre-existing chimney, have it’s condition and installation inspected before using. Make sure that the chimney meets all of the UL rating requirements listed above. Be aware that not all manufactured chimney is of the UL 103 HT type.

NOTE: It is recommended that you contact a licensed heating and cooling contractor (consult your local yellow pages) for chimney installation.

Manufactured chimney with the proper required UL listing is available from most home centers, hardware stores, and HVAC supply stores.

If you have access to the internet, you may wish to view chimney manufacturers’ information on-line. See, www.duravent.com, www.selkirkinc.com, or www.mtlfab.com.

Carefully follow chimney manufacturer's instructions. Use only a listed chimney. If your chimney starts at the ceiling (see figure 5 & figure 6) you will need enough 6" round black stove pipe to reach the ceiling. The top of the chimney must be at least three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within ten (10) feet (see figure 5 & figure 7).

 

Fig. 6  
Chimney Construction Through Roof:


Fig. 7   Chimney Connection to Firebox
Through Masonry Wall:

Venting to Existing Fireplace

In some instances, people desire to convert an existing fireplace for stove use. Usually, safe connection to an existing masonry chimney requires more work than using a prefabricated chimney.

The existing fireplace must be closed and sealed at the damper with high-temperature caulk, ceramic wool, or furnace cement. Prior to installation, clean and inspect the existing flue and smoke shelf. Installation should be designed so the system can be dismantled for periodic cleaning and inspection.

Before conversion, make sure the existing chimney is structurally sound, the chimney incorporates a flue liner and make sure it is in good condition. (A flue liner consists of clay tile that protects the brickwork of a chimney. If a chimney does not have a liner, or it is damaged, have it relined by a professional. Do Not use a chimney that is unlined or damaged!

If you have any question regarding the condition of the chimney, consult a qualified licensed contractor, qualified engineer, competent mason, certified Chimney Sweep, or a knowledgeable inspector. Consult your insurance company if you cannot find a qualified expert.

 

CAUTION: Not all fireplaces are suitable for conversion to a wood stove. Check with a qualified expert.

Many prefabricated fireplaces are of the "zero-clearance fireplace" category. These consist of multi-layered metal construction. They are designed with enough insulation and/or air cooling on the base, back and sides so they can be safely installed in direct contact with combustible floors and walls. 

Although many prefabricated fireplaces carry endorsements from nationally recognized organizations for use as fireplaces, they have not been tested for connection to wood stove heaters. Connecting a stove to such a device will void the manufacturer's warranty.

Steel-lined fireplaces are constructed with 1/4" firebox liner, an air chamber in connection with 8" of masonry. These can be safely used with wood burning stoves. They contain all the essential components of a fireplace, firebox, damper, throat, smoke shelf, and smoke chamber. Many look identical to masonry fireplaces and should be checked carefully before connecting a stove to them.

Venting a stove directly into a fireplace does not meet code and should not be attempted. (This constitutes connection to another appliance - the fireplace.) Combustion products will be deposited and build up in the firebox or fireplace. The stove warranty will be void with such an installation. Do not create a hazard in your home by connecting in this manner.

Fireplace Installation

Directly connecting the stovepipe into the existing masonry chimney (see figure 8 "Type A" fireplace conversion) of the fireplace is the only approved method of installation. This is a complicated and involved process and to insure safety should only by done by a qualified installer.

  1. An entry hole must be cut through the masonry and tile liner with minimal damage to the liner. At least 8" of liner must remain below the entry position. When locating the stove and stovepipe, all minimum clearances must be observed from combustible surfaces including mantels, combustible trimwork, ceilings and walls. Positioning the center of the stove pipe entry into the chimney 24" below the ceiling should insure proper clearance for a 6" stovepipe. 

  2. Install a metal or fire clay (5/8" minimum thickness) thimble. Make sure the thimble is flush with the inner surface of the chimney liner and does not protrude into the flue (see figure 3).

  3. Secure the thimble with refractory mortar. The thimble should be surrounded by 8" of solid unit masonry brickwork or 24" of stone.

  4. Install the stovepipe into the thimble as far as possible without extending past the flue lining (see figure 3 & figure 4).

  5. A small airspace (about 1/2") should remain between the stovepipe and thimble to allow for expansion of the pipe. Seal this airspace with high-temperature caulking or ceramic wool.

  6. Secure and seal the damper in the closed position using high-temp caulking, ceramic wool, or furnace cement. Also check to see if the chimney has a cleanout. If it does, make sure it is closed and sealed as well. A leaky cleanout will greatly reduce draft efficiency.

Fig. 8   Fireplace Conversion:

If you have any questions regarding venting your stove, contact the manufacturer or contact the National Fire Protection Association (NFPA) and request a copy of the latest editions of NFPA Standard 211 and NFPA Standard 908. 

Their address is:

Battery March Park, Quincy, MA 02269.


Operating Instructions

CAUTION: HOUSE FIRE HAZARDS

  • DO NOT STORE WOOD ON FLOOR PROTECTOR, UNDERNEATH STOVEPIPE OR ANY-WHERE WITHIN MINIMUM CLEARANCES FROM COMBUSTIBLE SURFACES SPECIFIED FOR THIS STOVE.

  • OVERFIRING MAY CAUSE A HOUSE FIRE. YOU ARE OVERFIRING IF THE STOVE OR CHIMNEY CONNECTOR GLOWS RED.

 

WARNING: EXPLOSION HAZARD

  • NEVER USE CHEMICALS, GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR FLAMMABLE LIQUIDS TO START OR“ FRESHEN-UP” A FIRE IN THE STOVE.

  • KEEP ALL FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, OUT OF THE VICINITY OF THE STOVE — WHETHER IN USE OR IN STORAGE.

 

OPERATING SAFETY PRECAUTIONS

1.   Never overfire this stove by building excessively hot fires as a house/building fire may result. you are overfiring the stove If stove or stovepipe begins to glow or turn red.

2.   Never build extremely large fires in this type of stove as damage to the stove or smoke leakage may result.

3.   Stove is HOT while in operation. Keep children, clothing, and Furniture away from hot stove. Contact may cause skin burns. Do not touch the stove
after firing until it has cooled.

4.   Provide air into the room for proper combustion.

5.   Inspect stovepipe every 60 days.
Replace immediately if stovepipe is rusting or leaking smoke into the room.


CAUTION: 
DO NOT OVERFIRE APPLIANCE.  Too much wood or burning non-recommended materials such as trash or flammable liquids may cause
overfiring. You are overfiring if the chimney connectors or stove glows red. Close the door, spin draft and damper immediately to reduce the air supply to the fire. This will slow down the fire.

This stove is designed to burn
WOOD FUEL ONLY.

Hardwood, 18" to 20" should be split and air dried (seasoned), for 6 months to obtain maximum burning efficiency. Wood should be stored in a dry, well ventilated area.
 

NOTICE: Use solid wood materials only. Do Not burn garbage or flammable fluids. Do Not Use Coal as Coal or charcoal will destroy the Grate and / or the Firebox.

NOTE: A 2” layer of sand or a layer of firebrick should be used as bottom insulation in the Boxwood stove. An optional cast iron grate, 26G, may be used instead of firebrick or sand. See Accessory Sheet included with this manual for ordering information.


Lighting

  1. Open draft damper fully to provide maximum draft.
  2. Open the feed door and place several wads of crushed paper in the firebox.
  3. Lay small stacks of kindling on the paper to start the fire.
  4. Light the paper and kindling, close the door and secure tightly.
  5. Add fuel after fire is burning briskly. Use care not to smother the kindling fire when adding wood. Close the door and secure tightly. 
  6. Adjust the draft damper and slide draft control. The more closed the slide draft is set, the lower and slower the fire will burn. The more open, the faster and hotter the fire will burn. Do not overfire the stove.

Adding Fuel

Add small amounts of fuel each hour or so
instead of piling large quantities of fuel at one time. This will insure a more complete combustion process and less buildup of tars, soot, or creosote will occur in the chimney.

  1. Always open draft damper before opening the feed door.
  2. When adding fuel be careful not to smother the fire. 
  3. Close the feed door and secure tightly. 
  4. Adjust the damper and slide draft control.
  5. Empty ashes regularly. Do not allow ashes to pile up higher than the top lip of the slide draft.
  6. Properly dispose of hot ashes (see Safety Instructions, item # 13.)
  7. Do not overfire the stove.
CAUTION: SLOW BURNING FIRES AND EX-TENDED USE MAY CAUSE EXCESSIVE CREOSOTE BUILDUP. IGNITION OF CREOSOTE BUILDUP OR OVERFIRING MAY CAUSE A CHIMNEY FIRE. CHIMNEY FIRES BURN EXTREMELY HOT AND MAY IGNITE SURROUNDING MATERIALS. IN CASE OF A CHIMNEY FIRE IMMEDIATELY LEAVE THE BUILDING AND CALL THE FIRE DEPARTMENT FROM A SAFE LOCATION.

Maintenance & Service Hints

ASH DISPOSAL:  Do not allow ashes to accumulate higher than the grate. Dispose of
properly. (See Safety Instructions)

CHIMNEY DRAFT: Draft is a function of the chimney, not the stove — do not expect the stove to draw. Smoke spillage into the house or excessive buildup of condensation or creosote in the chimney are warnings that the chimney is NOT functioning properly. Correct the problem before using the stove. Following are some possible causes for improper draft.

  1. The connector stovepipe may be pushed into the chimney too far, stopping the draft.

  2. If the chimney temperature is too cool, water will condense in the chimney and run back into the stove. Creosote formation will be rapid and may block the chimney. Operate the stove at a fire level high enough to keep the chimney warm to prevent condensation from forming.

  3. If the fire burns well but sometimes creates excess smoke or burns slowly, it may be caused by the chimney top being lower than another part of the house or a nearby tree. The wind blowing over a house or tree, falls on top of the chimney like water over a dam, beating down the smoke. The top of the chimney should be at least three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within ten (10) feet.

CREOSOTE FORMATION and REMOVAL:  Slow-burning wood produces tar and other organic vapors which combine with expelled moisture to form creosote. Creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. If ignited, this creosote creates an extremely hot fire which may ignite surrounding materials resulting in a building fire.

If creosote has accumulated, it should be removed. Failure to remove creosote may result in ignition and may cause a house/building fire. Creosote may be removed using a chimney brush or other commonly available materials from your local hardware retailer.

CHIMNEY INSPECTIONS:  The chimney connector and chimney should be inspected at the beginning of and at least twice a month during the heating season to determine if a creosote buildup has occurred.

Chimney fires burn very hot. If the chimney connector should glow red, reduce the fire by
closing the damper and spin draft control and immediately call the fire department.
 

CAUTION: A chimney fire may cause ignition of wall studs or rafters which were assumed to be a safe distance from the chimney. If a chimney fire has occurred, have your chimney inspected by a qualified expert before using again.

A fire in the stove may be smothered by pouring a large quantity of coarse salt, baking soda, or cool ashes on top of the fire.

STOVE JOINTS:  Required Tune-up.
This stove is manufactured with cast iron components. It does not have welded seams. Periodic "tune up" may be required by refilling and/or replacing the cement/joint mortar along the seams where the cast iron components meet.

Order replacement parts for the BX26E Boxwood stove

Wood stove accessories

 


This Vogelzang heating appliance is safe when installed properly and will provide you with years of service. However, always exercise good judgment when you are using this stove. You are dealing with FIRE! Fire is inherently dangerous and must be treated with respect. Stay warm and in good health!

Respectfully yours,

Steve Vogelzang

Proprietor

Company Testimony:

"For God so loved the world that he gave his only begotten Son, that whoever believes in Him shall not perish but have eternal life"

John 3:16

MADE IN CHINA

go backReplacement parts page

Cast Iron Wood and Coal Stoves Plate Steel Wood Stoves Circulator Wood and Coal Stoves
EPA CERTIFIED WOOD STOVES Add-on Furnaces Barrel Stove Kits Heat Reclaimers
Customer Comments Dealer Information Policies F. A. Q. ALL Stoves Home

Vogelzang International Corporation