DURANGO™ HIGH EFFICIENCY WOODSTOVE
EPA Certified (3.6 grams/hr)
Model TR008 Owners Manual

(Save this manual for future reference. Go to PDF format for printing.)
 

 
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
OR OPERATING THE STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
 

DO NOT USE THIS STOVE IN A
MOBILE HOME, MANUFACTURED HOME, TRAILER OR TENT
NO EXCEPTIONS
!

This stove meets
Test Standards:
UL 1482-1996 U.S.

SAFETY INSTRUCTIONS

SAFETY NOTICE: If this stove is not properly installed, a house/building fire may result. For your safety, contact local building or fire officials about permits, restrictions, and installation requirements for your area.


Read All Instructions carefully.

  1. The installation of this stove must comply with your local building code rulings. Please observe the clearances to combustibles (see figure 3, figure 4 & figure 5). Do not place furniture or other objects within the clearance area.

  2. Verify that the stove is properly installed before firing the stove for the first time. After reading these instructions, if you have any doubt about your ability to complete your installation properly, you must obtain the services of a professional licensed installer familiar with all aspects of safe and correct installation. DO NOT use temporary or makeshift compromises during installation.

  3. DO NOT store wood, flammable liquids or other combustible materials too close to the unit. Refer to certification label on back of unit and minimum clearances (see Locating Stove).

  4. Do not install this stove in a mobile home, manufactured home, trailer or tent (NO EXCEPTIONS! per HUD Federal Standard: 24 CFR Ch.XX).

  5. If any parts are missing or defective, please notify the dealer or manufacturer immediately. DO NOT OPERATE A STOVE THAT IS MISSING ANY PARTS!

  6. Do not tamper with combustion air control beyond normal adjustment capacities.

  7. Always connect this stove to a chimney and vent to the outside. Never vent to another room or inside a building. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

  8. DO NOT CONNECT a wood burning stove to an aluminum Type B gas vent. This is not safe. Use approved masonry or a UL 103 HT  Listed Residential Type and Building Heating Appliance Chimney. Use a 6" diameter chimney, that is high enough to give a good draft (see specifics in chimney installation instructions.)

  9. Be sure that your chimney is safely constructed and in good repair. Have the chimney inspected by the fire department or a qualified inspector. Your insurance company may be able to recommend a qualified inspector.

  10. Creosote or soot may build up in the chimney connector and chimney and cause a house/building fire. Inspect the chimney connector and chimney twice monthly during the heating season and clean if necessary (see Operating Instructions).

  11. In the event of a chimney fire, turn the air control to closed position, leave the building and CALL THE FIRE DEPARTMENT IMMEDIATELY! Have a clearly understood plan on how to handle a chimney fire by contacting your local or provincial fire authority for information on proper procedures in the event of a chimney fire.

  12. To prevent injury, do not allow anyone to use this stove who is unfamiliar with the correct operation of the stove.

  13. Do not operate stove while under the influence of drugs or alcohol.

  14. For further information on using your stove safely, obtain a copy of the National Fire Protection Association (NFPA) publication, "Using Coal and Wood Stoves Safely" NFPA No. HS-10-1978. The address of the NFPA is:
    Battery March Park, Quincy, MA  02269.

  15. Dispose of ashes in a metal container with a tight fitting lid. Keep the closed container on a noncombustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or picked up by a refuse collector.

  16. The paint used on your stove may give off smoke and/or odor during the first fires. This may occur during the first 12 to 15 fires until the paint has cured. After the paint has cured this will end and not reoccur. Persons with lung conditions or owners of susceptible domestic pets (such as birds) should take prudent precautions. Open windows and doors as needed to clear smoke and odor. If the stove is overfired, paint discoloration will occur.

  17. This stove has a painted surface which is durable but it will not stand rough handling or abuse. When installing your stove, use care in handling. Clean with soap and warm water when stove is NOT hot. Do not use any acids or scouring soap, as these solvents wear and dull the finish.

  18. The walls of the firebox may become slightly distorted after a period of use. A slight distortion will not affect the operation of the stove.

  19. While stove is in operation, all persons, especially young children should be alerted to the hazards from high surface temperatures. Keep away from a hot stove to avoid burns or clothing ignition.

  20. If small children will be in the same room as the stove during operation, provide a sturdy barrier to keep them at a safe distance from the stove. NEVER LEAVE SMALL CHILDREN UNSUPERVISED when they are in the same room as the stove.

  21. Keep stove area clear and free from all combustible materials, gasoline, and other flammable vapors and liquids.

  22. To prevent burns, always wear protective clothing, leather hearth gloves and eye protection, while tending the fire.

  23. While in operation, keep the feed door closed at all times except while tending the fire.

  24. Do not overfire the stove. Overfiring will occur if the feed door or ash clean-out cover are left open during operation. Such actions will result in very dangerous operating conditions.

  25. DO NOT ELEVATE FIRE! Build fire directly on the bottom of the firebox. This stove has not been tested with the use of grates, andirons, or other means of elevating fire and should not be used.

  1. All power cords and electrical appliances and/or assemblies must be kept outside of the clearance dimensions shown in this manual for combustible materials.

NOTE: A LICENSED PROFESSIONAL HEATING AND COOLING CONTRACTOR SHOULD BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE.

ASSEMBLY INSTRUCTIONS

NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages.
 

TOOLS REQUIRED FOR INSTALLATION

MATERIALS REQUIRED

Pencil

6 foot Folding Rule or Tape Measure

Tin Snips

Drill: Hand or Electric

1/8" diameter drill bit (for sheet metal screws)

 

Screwdrivers
(blade and Phillips types)

14mm Nut Driver or Ratchet with 14mm Socket

Safety Glasses

Gloves

(NOTE: The following items are NOT included with your stove)

Flooring Protection: 29" x 48" as specified 
(see Locating Stove)

Chimney Connection: 6" black steel (24 gauge minimum) straight stove pipe or elbow (as required)

1/2" Sheet Metal Screws

Chimney: Existing 6" Lined Masonry Chimney or 6" Inside Diameter listed Type HT chimney.

Furnace Cement (manufacturer recommends Rutland Code 78 or equivalent)

  

Refer to diagram and parts list.

CAUTION: STOVE IS HEAVY. Make sure you have adequate help and use proper lifting techniques whenever moving stove.

  1. Uncrate the stove and remove cardboard packing and protective poly bag. Remove BOTTOM HEAT SHEILD (# 16) from carton. (Save cardboard for further assembly.)

  2. Remove parts from inside stove. Parts include:
    Blower Assembly (# 29), Legs (# 5) and Hardware Pack (# 26-28) located inside firebox.
    NOTE: Stove body is HEAVY. Make sure you have adequate help to lift stove body and use proper lifting techniques. Stove may be lightened during installation by removing fire brick. Replace firebrick before using. There are five different sizes brick. Note the location of each while removing or refer to figure 6 for proper location inside firebox.

  3. Place flattened carton on floor to protect stove finish and lay onto it's side.

  4. Remove the hex nuts (# 28) from the leg mounting studs on the four corners of the bottom of the stove.

  5. Position the bottom heat shield (see Fig. 1 - LEG ASSEMBLY below) aligning the corner holes with the four leg mounting studs. The smaller cutout must align with the air intake in the bottom front of stove. NOTE: The stove MUST NOT  be operated without the bottom heat shield in place.

Fig. 1 - LEG ASSEMBLY. Bottom heat shield and leg assembly.

  1. Align each leg with the mounting stud and slide into place. Replace the leg mounting hardware (see hex nut in Fig. 1 - LEG ASSEMBLY above) after installing the leg. After all four legs have been installed, tighten all mounting hardware.   

  2. Return stove to the upright position.

  3. Attach the back heat shield assembly (# 2) to the rear of the stove. The closed end is positioned to the bottom of the stove with the open end up (see Fig. 2 - TOP VIEW below). Secure the back heat shield with four Phillips head machine screws using the threaded holes located in the rear side corners of the stove.

  1. Attach the heat shield deflector (# 17) to the top of the back heat shield assembly with three Phillips head machine screws. The angled lip of the deflector should face toward the front of the stove..

  2. Attach blower assembly to rear of the back heat shield with four Phillips head machine screws from the hardware pack. Make sure to position the ceramic gasket between the back heat shield and the blower assembly.

  3. After properly locating floor protector (see figure 3) to accommodate minimum stove clearances, place stove in position on floor protector.

  4. Route the power cord away from stove. Do not allow the power cord to touch any hot surfaces. Keep power cord at least 12”  from stove surfaces.

  5. Check to make sure that the bottom fire bricks (# 13) and ceramic fiber boards (parts # 18 & # 19) above the air tube assembly (# 6) have not shifted during shipping or assembly.

  6. Once stove is positioned, plug power cord into a grounded 120v outlet.


Locating Stove
 

CAUTION: (FIRE HAZARD) CARPETING AND OTHER COMBUSTIBLE MATERIAL SHALL NOT COVER THE FLOOR PROTECTOR. THESE MATERIALS MUST REMAIN OUTSIDE OF COMBUSTIBLE CLEARANCES. (see figure 3, figure 4 & figure 5)


  1. The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a listed floor protector, such as Hy-C or Imperial Model UL 3648BK or
    equivalent with 0.8 R factor. (NOTE: to calculate R-value of alternative materials see page
    20). The floor protector must extend at least 18” beyond the front of the access door, 6” to
    the sides, and must extend under and 2 inches beyond either side of the stove pipe if it is
    elbowed towards a wall (see figure 3 & figure 5) and consult local building codes and fire protection ordinances). A grouted ceramic floor tile installed per local building code is considered a durable equivalent.

  2. The stove must have its own flue. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING OTHER APPLIANCES.

  3. After observing the clearances to combustible materials (see figure 3 & figure 5), locate your floor protector accordingly (see figure 3) and carefully place the stove in your selected location. Install stove pipe, elbows, and thimble as required, utilizing either a recently cleaned and inspected 6” masonry chimney or a 6” i.d. listed type HT chimney.

  4. Use 6” round black stove pipe, not galvanized stove pipe. Secure each pipe section with three (3) sheet metal screws in each stove pipe and/or elbow joint to firmly hold the pipe sections together. DO NOT CONNECT THIS STOVE TO ANY AIR DISTRIBUTION OR DUCT SYSTEM.

  5. Recheck clearances from the stove, connector stove pipe, and corner clearances using the illustrations (see figure 3 & figure 5) and your local building codes or fire protection ordinances.
    NOTE: Drywall faced with brick or stone must be considered a combustible surface.

  6. DO NOT USE THIS STOVE IN A MOBILE HOME, MANUFACTURED HOME, TRAILER OR TENT
    NO EXCEPTIONS! (HUD Federal Standard: 24 CFR Ch.xx)

  7. The clearances provided are minimum dimensions determined by OMNI-Test Laboratories, Inc., the manufacturer’s testing laboratory. Installation of this stove must comply with the latest edition of NFPA 211 for reduced clearances and/or your local building code rulings. Use whichever minimum dimensions are LARGEST.

  8. This stove meets U.S. Test Standard UL 1482-1996.

  9. Always locate stove to provide a source of fresh air into the room where the unit is installed. Failure to do so may result in air starvation of other fuel burning appliances and the possible development of hazardous conditions.
     

CAUTION: FAILURE TO FOLLOW THESE MINIMUM CLEARANCE REQUIREMENTS MAY RESULT IN AN UNSAFE INSTALLATION AND COULD CAUSE A FIRE.

CAUTION: REPLACE FIREBRICKS BEFORE FIRING WOODSTOVE. POSITION FIREBRICKS SO NO GAPS REMAIN BETWEEN BRICKS.

Fig. 3    TOP VIEW Minimum Clearance Dimensions from Combustible Surfaces:

 

Fig. 4   Top View:  Minimum Corner Clearances from Combustible Surfaces

CORNER CLEARANCES
 

Fig. 5  Minimum Clearance Dimensions from Combustible Surfaces (front and side views)


FIREBRICK ASSEMBLY
 

CAUTION: REPLACE FIREBRICKS BEFORE FIRING WOODSTOVE.
POSITION FIREBRICKS SO NO GAPS REMAIN BETWEEN BRICKS.

Firebrick protects the stove body, extends the life of your stove and radiates heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping or assembly. If removed for ease of locating stove, firebrick must be replaced before firing. There are four different full-sized bricks (A, K, F, D) and three (E, G, H) with notches. See diagram, figure 6, below for proper positioning.
 

CAUTION: NEVER OPERATE STOVE WITH MISSING OR CRACKED FIRE BRICKS!

Fig. 6 - Firebrick Installation


 

Connector Pipe Installation
 

  1. The tapered end of the connector stovepipe fits into the stove flue collar.

  2. Horizontal pipe runs must slope upwards towards the chimney at least 1/4" per foot of horizontal run.

  3. You must have at least 18 inches of clearance between any horizontal piping and the ceiling.

  4. The pipe cannot extend into the chimney flue (figure 7).

  5. Secure pipe/elbow sections with three (3) sheet metal screws at each joint to make the piping rigid.

  6. It is recommended that no more than two (2) 90° bends be used in the stovepipe installation. The use of more than two 90° bends may decrease the amount of draw and possibly cause smoke spillage. Where possible, use only corrugated (nonadjustable) elbows. These provide a better seal.

  7. The connector pipe must not pass through an attic or roof space, closet, or any concealed space, or floor, ceiling, wall or combustible construction. (See Chimney Connector Systems and Clearances.) A UL 103 HT Listed chimney must be used from the first penetration of ceiling or wall to the chimney cap. Never use single wall connector pipe as a chimney - a house fire could result.
     

NOTE: CONNECTOR PIPE IS NOT INCLUDED. TO PURCHASE, VISIT YOUR LOCAL HARDWARE, HOME OR BUILDING CENTER.  See Locating Stove for additional specifications.

Fig. 7  Stovepipe / Flue Connections:

CORRECT WRONG WRONG 


CHIMNEY CONNECTIONS

The stove must be connected to either a masonry or manufactured metal chimney built and tested to the specifications listed on the previous pages.

Chimneys perform two functions:  

  1. As a means of exhausting smoke and flue gases which are the result of fuel combustion. 

  2. The chimney provides "draft" which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. This stove relies on natural draft to operate.

NOTICE: Always provide a source of fresh air into the room where the stove is located. Failure to do so may result in air starvation of other fuel burning appliances and the possible development of hazardous conditions, fire or death.

Note, your stove does not create draft. Draft is provided by the chimney. To achieve proper draft your chimney must meet the three minimum height requirements. (See figure 9, figure 10, figure 11) A minimum of 0.05 w.c. (measured in water column) is required for proper drafting to prevent back puffing, smoke spillage, and to maximize performance. (Gauges to measure draft are readily available at stove stores and are economical to rent or purchase.)

Factors such as wind, barometric pressure, trees, terrain and chimney temperature can have an adverse effect on the draft. The manufacturer cannot be held responsible for external factors leading to less than optimal drafting.

Should you have a problem with inadequate draft, you should contact a licensed heating and cooling contractor for assistance in solving the problem.

IMPORTANT Installation Points

  1. Size chimney flue to stove collar. This stove requires a 6” diameter flue.

  2. Never connect this unit to a chimney serving another appliance.

  3. The chimney must meet all minimum height requirements.

  4. Never use a chimney to ventilate a cellar or basement.

  5. Contact your local building authority for approved methods of installation and any necessary permits and/or inspections.
     

MASONRY CHIMNEY

Before using an existing masonry chimney, clean the chimney, inspect the flue liner and make any repairs needed to be sure it is safe to use. Make repairs before attaching the stove. The connector stove pipe and fittings you will need to connect directly to a masonry chimney are shown in figure 8.

If the connector stove pipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local building and fire codes and latest edition of NFPA 211.

If there is a cleanout opening in the base of the chimney, close it tightly.

MANUFACTURED CHIMNEY

REFER TO CHIMNEY AND CHIMNEY CONNECTOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE.

Use only 6” diameter listed chimney UL 103 HT type. Chimney made to this listing is High Temperature rated to 2100 degrees Fahrenheit. Use chimney from only one manufacturer. Never mix brands. Carefully follow the chimney manufacturer’s stated requirements and clearances. Use the chimney manufacturer’s attic guards, roof supports, flashing and fire stops when passing through a ceiling. Use a listed thimble when passing through a combustible wall. Do not use makeshift compromises during installation. Never use a single-wall connection pipe as a chimney!

When using a pre-existing chimney, have it’s condition and installation inspected before using. Make sure that the chimney meets all of the UL rating requirements listed above. Be aware that not all manufactured chimney is of the UL 103 HT type.

Fig. 8   Masonry Chimney Connection
 

Fig. 9   Chimney Construction Through Attic Space:

NOTE: It is recommended that you contact a licensed heating and cooling contractor (consult your local yellow pages) for chimney installation.

Manufactured chimney with the proper required UL listing is available from most home centers, hardware stores, and HVAC supply stores.

You may wish to view chimney manufacturers’ information on-line. See, www.duravent.com, www.selkirkinc.com, www.mtlfab.com.
 

Fig. 10  Chimney Construction Through Roof:


Fig. 10 Chimney Connection to Firebox
Through Masonry Wall:

VENTING TO EXISTING FIREPLACE

In some instances, people desire to convert an existing fireplace for stove use. Usually, safe connection to an existing masonry chimney requires more work than using a prefabricated chimney. The existing fireplace must be closed and sealed at the damper with high-temperature caulk, ceramic wool, or furnace cement. Prior to installation, clean and inspect the existing flue and smoke shelf. Installation should be designed so the system can be dismantled for periodic cleaning and inspection. Before conversion, make sure the existing chimney is structurally sound, the chimney incorporates a flue liner and make sure it is in good condition. (A flue liner consists of clay tile that protects the brickwork of a chimney. If a chimney does not have a liner, or it is damaged, have it relined by a professional. Do Not use a chimney that is unlined or damaged!) If you have any question regarding the condition of the chimney, consult a qualified licensed contractor, qualified engineer, competent mason, certified Chimney Sweep, or a knowledgeable inspector. Consult your insurance company if you cannot find a qualified expert.

 

CAUTION: Not all fireplaces are suitable for conversion to a wood stove. Check with a qualified expert.

Many prefabricated fireplaces are of the "zero-clearance fireplace" category. These consist of multi-layered metal construction. They are designed with enough insulation and/or air cooling on the base, back and sides so they can be safely installed in direct contact with combustible floors and walls.

Although many prefabricated fireplaces carry endorsements from nationally recognized organizations for use as fireplaces, they have not been tested for connection to wood stove heaters. Connecting a stove to such a device will void the manufacturer's warranty.

Steel-lined fireplaces are constructed with 1/4" firebox liner, an air chamber in connection with 8" of masonry. These can be safely used with wood burning stoves. They contain all the essential components of a fireplace, firebox, damper, throat, smoke shelf, and smoke chamber. Many look identical to masonry fireplaces and should be checked carefully before connecting a stove to them.

Venting a stove directly into a fireplace does not meet code and should not be attempted. (This constitutes connection to another appliance - the fireplace.) Combustion products will be deposited and build up in the firebox or fireplace. The stove warranty will be void with such an installation. Do not create a hazard in your home by connecting in this manner.

FIREPLACE INSTALLATION

Directly connecting the stovepipe into the existing masonry chimney (see figure 12 "Type A" fireplace conversion) of the fireplace is the only approved method of installation. This is a complicated and involved process and to insure safety should only by done by a qualified installer.

  1. An entry hole must be cut through the masonry and tile liner with minimal damage to the liner. At least 8" of liner must remain below the entry position. When locating the stove and stovepipe, all minimum clearances must be observed from combustible surfaces including mantels, combustible trimwork, ceilings and walls. Positioning the center of the stove pipe entry into the chimney 24" below the ceiling should insure proper clearance for a 6" stovepipe. 

  2. Install a metal or fire clay (5/8" minimum thickness) thimble. Make sure the thimble is flush with the inner surface of the chimney liner and does not protrude into the flue (see figure 7.

  3. Secure the thimble with refractory mortar. The thimble should be surrounded by 8" of solid unit masonry brickwork or 24" of stone.

  4. Install the stovepipe into the thimble as far as possible without extending past the flue lining (see figure 7).

  5. A small airspace (about 1/2") should remain between the stovepipe and thimble to allow for expansion of the pipe. Seal this airspace with high-temperature caulking or ceramic wool.

  6. Secure and seal the damper in the closed position using high-temp caulking, ceramic wool, or furnace cement. Also check to see if the chimney has a cleanout. If it does, make sure it is closed and sealed as well. A leaky cleanout will greatly reduce draft efficiency.

Fig. 12   Fireplace Conversion:

 

If you have any questions regarding venting your stove, contact the manufacturer or contact the National Fire Protection Association (NFPA) and request a copy of the latest editions of NFPA Standard 211 and NFPA Standard 908. 

Their address is:

Battery March Park, Quincy, MA 02269.
 


OPERATING INSTRUCTIONS

CAUTION: HOUSE FIRE HAZARDS

  • Do not store wood on floor protector, underneath stovepipe or anywhere within minimum clearances from combustible surfaces specified for this stove.

  • Overfiring may cause a house fire. You are overfiring if the stove or chimney connector glows red.

 

OPERATING SAFETY PRECAUTIONS

1.   Never overfire this stove by building excessively hot fires as a house/building fire may result. you are overfiring the stove If stove or stovepipe begins to glow or turn red.

2.   Never build extremely large fires in this type of stove as damage to the stove or smoke leakage may result.

3.   Do not build fire TOO CLOSE TO GLASS.

4.   Unit is HOT while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. Do not touch the stove after firing until it has cooled.

5.   Provide air into the room for proper combustion.

6.   Inspect stovepipe every 60 days.
Replace immediately if stovepipe is rusting or leaking smoke into the room.

WARNING: EXPLOSION HAZARD

  • Never use chemicals, gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar flammable liquids to start or "freshen-up" a fire in the stove.

  • Keep all flammable liquids, especially gasoline, out of the vicinity of the stove -- whether in use or in storage.

This stove is designed to burn
WOOD FUEL ONLY!

Hardwood, 24" to 26" should be split and air dried (seasoned), for 6 months to obtain maximum burning efficiency. Wood should be stored in a dry, well ventilated area.
 
 

NOTICE: Use solid wood materials only! Do NOT burn garbage or flammable fluids. Do not use coal - this stove is not designed to  accommodate the air flow (draft) necessary to properly burn coal or coal products. Do not elevate fire or use grates or andirons. Build fire directly on bottom of firebox.

OPTIMAL FUEL CONSUMPTION

This stove is designed to get the most efficient transfer of heat energy from the wood fuel and radiate it into your living environment. The fire box introduces combustion air through three sources. (1) Immediately beneath the door opening below the window is a Lower Primary Air Orifice (LPAO). (2) The door air inlet control brings air into the firebox and controls the rate of burn (and the amount of heat the stove radiates). (3) The secondary air tubes at the top of the firebox are designed to ignite the combustion gases (smoke) given off by the burning wood and increases the efficiency of the stove and reduces chimney emissions.

Smoke given off by burning fuel consists of very small organic liquid droplets. If these droplets condense, they form a sticky tar-like substance called creosote. When operated properly, this stove is designed to burn these droplets. Burning these droplets releases heat that would otherwise be lost up the chimney as smoke. Following the instructions below will help you operate your stove properly to maximize the stove’s performance. Actual performance is dependent on chimney height, weather, log size, wood species and moisture content. Some experimentation will initially be required to find that “sweet spot” where your stove performs best. The following will give you a starting point to find your optimum settings.

When first loading fuel set the door air inlet control at the wide open position for at least 15–20 minutes. When the stove is working properly you should be able to observe secondary combustion flames above the fuel pieces in front of the secondary air tubes at the top of the firebox. These secondary flames should continue to burn after the primary air inlet is reset from wide open to the desired operating setting. If the flames do not continue to burn, open the air control to re-establish the secondary flames then slowly reset the air control to the desired setting. Initially it may take several attempts to figure your stove out. But once you find the operating “sweet spot” and the correct mix of procedures to get there, only minor adjustments will be necessary.

The best indicator of a properly operating stove is to look for smoke coming out of the chimney. You may see steam emissions that will quickly dissipate.
Smoke will thin but continue to drift without totally disappearing. If you do detect smoke emissions, open the air control a little bit, let the stove adjust for 10–15 minutes and re-check your chimney. Remember – visible smoke represents lost heat.

NOTICE - INITIAL BURNS TO CURE PAINT

Because of the high operating temperatures, this stove uses a special high-temp paint which requires a series of burns to cure the paint for durability and
a lifetime of service.

Proper curing of the high-temp paint requires a series of three initial burns. The stove should be allowed to cool off between each burn. The first two burns should be small fires and low temperatures (250 degrees F) for a duration of 20 minutes each. The third fire should be at a medium-high temperature (500 F to 700 F) for twenty minutes. Provide adequate cross ventilation to clear any smoke or odor caused by initial firings.

STARTING A FIRE

  1. Set air inlet control to fully open position.

  2. Open the feed door and place several wads of crushed paper in the firebox.

  3. Cover the paper with a generous amount of kindling in a teepee fashion and a few small pieces of wood.

  4. Ignite the paper and leave the door open slightly. DO NOT LEAVE STOVE UNATTENDED WITH DOOR OPEN!

  5. Add large pieces of wood as the fire progresses being careful not to overload. (Do not fill firebox beyond firebrick area.) An ideal coal bed of 1 –2” should be established to achieve optimum performance.

  6. This unit is designed to function most effectively when air is allowed to circulate to all areas of the firebox. TIP: If ash or coals remain in the stove, make sure to clear them away from the Lower Primary Air Orifice (LPAO) and rake a slight (1-to-2 inch wide) trough down the center of the coal bed from front to back prior to loading the fuel

  7. Once fuel has been loaded, close the door and leave the air inlet control fully open until fire is well established (at least 15–20 minutes) being careful not to overfire (if any of the exterior parts of the stove or chimney connections begin to glow you are overfiring the stove).

  8. Re-adjust the door air inlet control to desired burn rate. (If excessive smoke fills the firebox, open air inlet control slightly until flames resume and wood is sufficiently ignited.) The basic rule of thumb is “closed - low,” “half way open - medium” and “fully open - high.”

NOTE: The four (4) inlet holes in the primary air inlet control slide are designed to remain partially open with slide in the closed position.

ADDING FUEL

If the coal bed is not hot and glowing, rake the coals to the front of the stove, close the door and adjust the air inlet control to the wide open position. Let the coals re-heat for 10–15 minutes. When hot and glowing, spread them out and place your next fuel load into the stove (make sure no coals or ashes block the LPAO). Leave the door air inlet control in the wide open position for 15–20 minutes.

Fuel load size can vary but should be kept 1–2 inches below the secondary air tubes. Also position the fuel to leave space so the air from the inlet can work down between the pieces of fuel. This reduces the time it takes for new fuel to burn properly.
 

  1. When refueling, adjust air inlet control to the fully open position. When fire brightens, slowly and carefully open the door. This procedure will prevent gases from igniting causing smoke and flame spillage.

  2. Add fuel being careful not to overload or overfire the stove.

  3. When adding fuel be careful not to smother the fire. Do not build fires against glass and make sure the coal bed does not obstruct the air inlet.

  4. Close the feed door and secure tightly.

  5. Adjust the air inlet control as described above.

  6. Empty ashes regularly. Do not allow ashes to pile up (see Safety Instructions).

  7. Properly dispose of hot ashes (see Safety Instructions).

  8. Do not overfire the stove (overfiring is when any part of the stove exterior or chimney connections glow).

BLOWER OPERATION

If your stove is equipped with the blower attachment, follow these instructions for optimal operation.

LOW (door air control is fully closed to 1/4 open): Turn the fan on 30 minutes after fuel has been added and set the fan speed at low.

MEDIUM (door air control 1/4 to 3/4 open): Wait 15 minutes after fuel has been added and set the fan speed control at high.

HIGH (door air control wide open): Wait 5 minutes after fuel has been added and set the fan speed at high.

CREOSOTE – Formation and Removal

When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire and can accumulate on the flue lining. If ignited, this creates an extremely hot fire in the chimney which may ignite surrounding materials resulting in a building fire.

The chimney connector and chimney should be inspected (at least) twice a month during the heating season to determine if a creosote buildup has occurred. If it has, it should be removed. Failure to remove creosote may result in ignition and may cause a house/building fire. Creosote may be removed using a chimney brush or other commonly available materials from your local hardware retailer.

Chimney fires burn very hot. If the unit or chimney connector should glow red, reduce the fire by closing the inlet air control and immediately call the fire department.
 

CAUTION: DO NOT OVERFIRE APPLIANCE. YOU ARE OVERFIRING IF THE CHIMNEY CONNECTORS OR STOVE GLOWS RED. CLOSE THE DOOR AND SHUT DAMPER IMMEDIATELY TO REDUCE THE AIR SUPPLY TO THE FIRE. THIS WILL SLOW DOWN THE FIRE.


CAUTION: Slow burning fires and extended use may cause excessive creosote buildup. Ignition of creosote buildup or overfiring may cause a chimney fire. Chimney fires burn extremely hot and may ignite surrounding materials. In case of a chimney fire call the fire department immediately.

 

CAUTION: A chimney fire may cause ignition of wall studs or rafters which were assumed to be a safe distance from the chimney. If a chimney fire has occurred, have your chimney inspected by a qualified Expert before using again.

 
A fire in the firebox may be smothered by pouring a large quantity of coarse salt, baking soda, or cool ashes on top of the fire.

Preventing Creosote Buildup

  1. Burn with air control open for several minutes at numerous intervals throughout the day during the heating season, being careful not to over-fire the unit.

  2. Burn stove with air inlet control wide open for 15–20 minutes every time you apply fresh wood. This allows wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be deposited within the heating system.

  3. BURN ONLY SEASONED WOOD. Avoid burning wet or green wood. Seasoned wood has been dried for at least one year.

  4. A small fire is preferable to a large smoldering one that can deposit creosote within the heating system.

  5. Establish a routine for the handling of fuel, wood burner and firing technique. Check daily for creosote build-up until experience shows how often you need to clean for safe operation. Be aware that the hotter the fire, the less creosote is deposited and weekly cleanings may be necessary in mild weather even though monthly cleanings may be enough in colder months.

WARNING: IN CASE OF CHIMNEY FIRE (1) CLOSE AIR INLET CONTROL
(2) GET OUT OF THE HOUSE (3) CALL THE FIRE DEPARTMENT.


CHIMNEY DRAFT

Draft is a function of the chimney, not the stove — do not expect the stove to draw. Smoke spillage into the house or excessive buildup of condensation or creosote in the chimney are warnings that the chimney is NOT functioning properly. Correct the problem before using the stove. Following are some possible causes for improper draft.

  1. The connector stovepipe may be pushed into the chimney too far, stopping the draft.

  2. If the chimney is operating too cool, water will condense in the chimney and run back into the stove. Creosote formation will be rapid and may block the chimney. Operate the stove at a fire level high enough to keep the chimney warm preventing this condensation.

  3. If the fire burns well but sometimes creates excessive smoke or burns slowly, it may be caused by the chimney top being lower than another part of the house or a nearby tree. The wind blowing over a house or tree, falls on top of the chimney like water over a dam, beating down the smoke. The top of the chimney should be at least three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within ten (10) feet.
     

NOTE: A draft reading of 0.05 to 0.06 W.C. (Water Column)
is suggested for proper burning of this stove.

GLASS CARE

The following usage and safety tips should be observed:

  1. Inspect the glass regularly for cracks and breaks. If you detect a crack or break, extinguish the fire immediately and contact the manufacturer for a replacement.

  2. Do not slam the door or otherwise impact the glass. When closing doors, make sure that logs or other objects do not protrude to impact the glass.

  3. Do not build fires against (or that might fall against) the glass.

  4. Do not clean the glass with materials that may scratch (or otherwise damage) the glass. Scratches on the glass can develop into cracks or breaks during operation.

  5. Never attempt to clean the glass while the unit is hot. If deposits are not very heavy, normal glass cleaners are adequate using a soft, non-abrasive cleaning pad. Heavier deposits may be removed with oven cleaners.

  6. Never put substances which can ignite explosively in the unit. Even small explosions in confined areas can blow out the glass.

GLASS REPLACEMENT

Caution : Replace glass ONLY with 5mm High Temperature ceramic glass of the proper size. Do not use tempered glass or double thickness window glass!

Gasket and Glass cleaning products are available at local retail home centers. Manufacturers of cleaning products include, A.W. Perkins Co. (www.awperkins.com) or Rutland Products (www.rutland.com).

After extensive use, the gasket material which provides glass and door seal may lose it’s resiliency and will need to be replaced. Inspect glass and door gaskets periodically to ensure proper seal; if gaskets become frayed or worn, replace immediately.

Glass Replacement Procedure:

  1. Ensure appliance is not in operation and is thoroughly cooled.

  2. Remove screw and glass clip. (See parts list and diagram.)

  3. Lift glass out from glass clip.

  4. Remove old gasket and clean glass.

  5. Replace new gasket starting at the bottom of glass working along edges, being sure to center gasket channel on glass.

  6. Trim to length and butt ends together.

  7. Replace glass into door, being sure not to overtighten screw and clip.

Door Gasket Replacement Procedure:

  1. Ensure appliance is not in operation and is thoroughly cooled.

  2. Remove old door gasket and clean channel.

  3. Using an approved, high temperature gasket cement, apply a thin coat in bottom of channel.

  4. Starting at hinge side of door, work gasket into channel around door unit, end butt and trim to length.

  5. Close door and allow three to four hours for cement to set before firing appliance.

WIRING DIAGRAM for TR008 DURANGO™ BLOWER ASSEMBLY:

NOTICE: DO NOT ALLOW POWER CORD TO TOUCH HOT SURFACES! KEEP POWER CORD AT LEAST 12" FROM STOVE OR PIPE SURFACES.

FLOOR PROTECTOR MATERIALS CALCULATIONS

This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions for Locating Stove, step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.

Alternate materials may be rated with C-factor (Thermal Conductance) or k-factor (Thermal Conductivity) ratings which must be converted to R-value to determine if the alternate material meets the tested requirements. The following instructions provide the proper information and formulas for conversion to R-value.

To determine if alternate materials are acceptable follow this sequence.

  1. Convert material specifications to R-value:

    1. R-value given — no conversion necessary

    2. k-factor is given with a required thickness (T) in inches:   R = 1/k x T

    3. C-factor is given: R = 1/C

  2. Determine the R-value of proposed alternate floor protector:

    1. Use formulas in step 1 above to calculate R-value of proposed material(s).

    2. For multiple layers, add R-values of each layer to determine overall R-value.

  3. If the overall R-value of the floor protector system is equal to or greater than the floor protector specifications given, the alternate is acceptable.

Definitions:

Thermal conductance (C)  = _  BTU   _ 
(hr)(ft2)(°F)
=     W    
(m2)(°K)
   
Thermal conductivity (k)  = (Btu)(inch)
(hr)(ft2)(°F)
=     W    
(m)(°K)
=     Btu    
(hr)(ft)(°F)
Thermal resistance (R)  = (ft2)(hr)(°F)
Btu
= (m2)(°K)
W
   

Example:

The specs of floor protector material should be 3/4-inch thick material with a k-factor of 0.84.
The proposed alternative material is 4" brick with a C-factor of 1.25 over 1/8-inch mineral board
with a k-factor of 0.29.

Step 1: Convert specs to R-value.

R = 1/k x T = 1/0.84 x 0.75 = 0.893 System must have a R-value of 0.893 = Rspecs

Step 2: Calculate R-value of individual components

4" Brick with C-factor = 1.25. R = 1/C = 1/1.25 = 0.80 = Rbrick
1/8-inch (0.125") mineral board with k-factor = 0.29. R = 1/0.29 x 0.125 = 0.431 = Rmin.brd.

Step 3: Add R-values of components to get total R-value of system

Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem

Step 4: Compare Rsystem to Rspecs

Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative.

Order replacement parts for the TR008 Durango High-Efficiency Stove

Wood stove accessories

Chimney connector systems and clearances 


This Vogelzang heating appliance is safe when installed properly and will provide you with years of service. However, always exercise good judgment when you are using this stove. You are dealing with FIRE! Fire is inherently dangerous and must be treated with respect. Stay warm and in good health!

Respectfully yours,

Steve Vogelzang

Proprietor

Company Testimony:

"For God so loved the world that he gave his only begotten Son, that whoever believes in Him shall not perish but have eternal life"

John 3:16

MADE IN CHINA

go backReplacement parts page

Cast Iron Wood and Coal Stoves Plate Steel Wood Stoves Circulator Wood and Coal Stoves
EPA CERTIFIED WOOD STOVES Add-on Furnaces Barrel Stove Kits Heat Reclaimers
Customer Comments Dealer Information Policies F. A. Q. ALL Stoves Home

Vogelzang International Corporation